User`s guide
4-88 Configuring Your Server
Described below are procedures based on assumption:
One of the Hard Disk Drives failed in a RAID5 VD configured with three Hard Disk Drives.
Replace the failed Hard Disk Drive with a new one after turning off the power of the server. The Auto Rebuild feature is
disabled for non-hot-swap replacement. Use the Manual Rebuild feature to recover the virtual drives as described below.
1. Start WebBIOS.
Make sure that the status for the replaced Hard Disk Drive is indicated as "Unconfigured Good" in the right frame of
the Top Menu.
In the example below, the Hard Disk Drive in slot number 2 has been replaced.
The indication "PD Missing: BackPlane 252: Slot2" means that the Hard Disk Drive in the VD installed in slot
number 2 has been removed.
2. Select the newly connected Hard Disk Drive (the Hard Disk Drive in slot number 2 in the example) from the right
frame of Top Menu.
3. The properties for the Physical Drive are displayed.