User`s guide
Configuring Your Server 4-41
Check Consistency
Run LSI Software RAID Configuration Utility
Perform Check Consistency
Exit LSI Software RAID Configuration Utility
1. Run LSI Software RAID Configuration Utility.
2. Select "Check Consistency" from the TOP menu.
The "Virtual Drives" screen appears.
3. Move the cursor onto the virtual drive to be checked, and press Space to select it.
4. When the virtual drive has been selected, press F10 to start consistency check..
5. A confirmation screen appears. Select "Yes".
The consistency check starts.
When the progress bar in the "Check Consistency Progress" screen indicates 100%, the consistency check is
completed.
6. Press Esc to return to the TOP menu and exit LSI Software RAID Configuration Utility.
IMPORTANT: Be sure to execute Check Consistency after creating the configuration.