User`s guide
7-16
NovaScale R422-E2/R422-INF-E2 Installation and User's Guide
Remote Access Conguration
Remote Access
This allows the user to enable the Remote Access feature. The options are
Disabled and Enabled. If Remote Access is set to Enabled, the following items
will display:
Serial Port Number
This feature allows the user decide which serial port to be used for Console
Redirection. The options are COM 1 and COM 2.
Serial Port Mode
This feature allows the user to set the serial port mode for Console Redirection.
The options are 115200 8, n 1; 57600 8, n, 1; 38400 8, n, 1; 19200 8, n, 1;
and 9600 8, n, 1.
Flow Control
This feature allows the user to set the ow control for Console Redirection.
The options are None, Hardware, and Software.
Redirection After BIOS POST
Select Disabled to turn off Console Redirection after Power-On Self-Test
(POST). Select Always to keep Console Redirection active all the time after
POST. (Note: This setting may not be supported by some operating systems.)
Select Boot Loader to keep Console Redirection active during POST and Boot
Loader. The options are Disabled, Boot Loader, and Always.
Terminal Type
This feature allows the user to select the target terminal type for Console
Redirection. The options are ANSI, VT100, and VT-UTF8.
VT-UTF8 Combo Key Support
A terminal keyboard denition that provides a way to send commands from a
remote console. Available options are Enabled and Disabled.
Sredir Memory Display Delay
This feature denes the length of time in seconds to display memory information.