3-23
Managing Domains
Deselect All Cancels all selected operations.
Power On All Powers on all INACTIVE domains.
Power Off All Powers off all RUNNING domains.
Force Power Off All Forcibly powers off all RUNNING or HUNG domains.
Deselect Cancels the selected operation for this domain.
Power On Powers on this domain if INACTIVE.
Power Off Powers off this domain if RUNNING.
Force Power Off Forcibly powers of this domain if RUNNING or HUNG.
Execute Applies all selected operations.
Cancel Cancels all selected operations.
Figure 44. Multiple power dialog - quadri-domain example
3. Click Force Power Off All Execute or select the required domain Force Power Off radio
buttons and click Execute to to override the Operating System and forcibly power down
the selected domains and associated hardware components without closing running
applications and saving data.
Power Off States
POWERING DOWN
INACTIVE
Table 12. Power-off states
Once the Power Off sequence has been successfully completed, INACTIVE is displayed in
the Domain Status panel and the Power On button becomes accessible.
For a detailed view of the Power Off sequence, click Powering View in the Toolbar. See
Viewing Domain Powering Sequences, on page 3-32.
Note:
If an error message is displayed in the Domain Status panel, the Power Off sequence has
failed. See What To Do if an Incident Occurs, on page 3-42.