User`s guide

4-43
Monitoring the Server
System Functional Status / Expected Domain State
Icon System Functional Status Expected Domain State
Green
NORMAL RUNNING
Yellow
WARNING RUNNING
Orange
CRITICAL
INACTIVE (auto Power OFF) / RUNNING
An automatic Power OFF request may be sent
by PAM software to the domain Operating
System:
- If the domain Operating System is
configured to accept PAM Power OFF
requests, it automatically saves data, closes
open applications and shuts down.
- If the Operating System is not configured to
accept PAM Power OFF requests, you are
Orange
Flashing
CRITICAL
- If the Operating System is not configured to
accept PAM Power OFF requests, you are
advised to manually save data, close open
applications and shut down the Operating
System.
Note:
When system functional status is FATAL, the
icon does not always remain red. Therefore,
an orange functional status icon may indicate
a FATAL hardware status.
Red
FATAL
INACTIVE
An automatic Force Power OFF command may
be performed by PAM software on the domain
Operating System.
Note:
Red
Flashing
FATAL
Operating System.
Note:
The Operating System does not have time to
save data and close applications before it is
shut down.
Purple
NOT ACCESSIBLE INACTIVE
Table 27. CSS functional status / domain state
5. Click the faulty hardware element to open the corresponding Hardware Status page.
6. Check Power and Temperature tabs. If a power and/or temperature indicator is NOT
green, a power- and/or temperature-specific fault has occurred. See Power Status
Indicators and Temperature Status Indicators, on page 4-18.
7. Click Display Faults List for direct access to server logs. If the Display Faults List button is
not accessible, click History Manager System PAM History for the corresponding
log. See Viewing Detailed Hardware Status, on page 4-15.
8. Expand the log for direct access to the corresponding Help File (at the bottom of the
page). The Help File explains the message and how to deal with the incident.
Important:
To maintain a trace of transient faults, PAM Tree functional and/or presence status indicators
will not change color until the domain has been powered OFF/ON, even although the error
has been corrected.