Installation guide

2-15
Setup Procedure
10.Click Power On to power up the server domain and associated hardware components.
When prompted, select View Power-On Logs to monitor test progress.
The following message is displayed in the Domain State field:
Powering on (test)
The test takes 2 to 3 minutes to complete. The last message (Step 99) in the Power-On
Logs information box indicates test result status:
if all tested ring connections are correct, OK is displayed,
if at least one tested ring connection is incorrect, KO is displayed. The system
functional status icon turns RED:
- open the Domain Fault List for details,
- click the Refresh Tree
button in the PAM Tree toolbar to refresh the PAM Tree
and update hardware functional status. Open the corresponding Hardware Fault
List for further details.
Note:
If Power-On is refused, a mandatory resource is missing and the ring test cannot be
performed. Open the PAMHistory file (History Manager -> System -> PAMHistory) for details
about the missing resource.