User`s guide
4-28
User’s Guide
Excluding a Hardware Element and Checking Exclusion Status
As Customer Administrator, you can logically Exclude a redundant hardware element from
the domain until it has been repaired or replaced. Exclusion is taken into account at the next
domain power ON. Hardware exclusion status can be viewed from the Domain Hardware
Details page. See Excluding / Including Hardware Elements, on page 4-17.
Checking, Testing and Resetting the PMB
The PMB is located in the module at the base of the cabinet and links the server to the PAP
unit via an Ethernet link. You may be required to carry out the following checks / actions:
• Check that PMB LED #0 is blinking green (PMB booted correctly):
When the system is powered on, the 7 activity and status LEDs (LED #1–LED #7) are
switched off and LED #0 is blinking.
• Check that PMB code wheels are set as follows:
CSS Cabinet Hexadecimal Code
(0 to F)
CSS Module Hexadecimal Code
(0 to F)
0 0
• Check that the Ethernet cable linking the server to the PAP unit is correctly inserted and
that the Ethernet link LED is green.
• Check the PAP – PMB link by pinging the PAP and the PMB:
PAP Address
PMB Address
10.10.240.240 10.10.0.1
• Reset the PMB by pressing the RESET button. PMB firmware will be rebooted.
LED7
LED4
LED3
LED0
LED4 to LED7: orange
LED0 to LED3: green
System activity and status LEDs
PMB status LED
Orange LED
OFF = OK
ON = PMB hot–plugged
Green LED: Ethernet link status (ON = OK)
Yellow LED: Link activity (ON = transmit)
CSS
Module
Code wheels
Load push–button
Reset PMB
Reserved
Serial port (DB9)
(reserved)
Ethernet connector
PAP link
Figure 54. Server PMB