User`s guide

4-19
Monitoring the System
Hardware Exclusion Guidelines
Hardware Element Exclusion Guidelines
IMPORTANT:
To ensure server operation and availability, the following core hardware elements
MUST NOT be excluded from the domain:
IOB_0,
IOB_0 HubLink_1,
IOR_0,
QBB FanBox_0.
IOB IOB_0 CANNOT be excluded from the domain. The domain
will not power up if IOB_0 is excluded.
Note:
If IOB_0 is excluded, IOR_0 will be automatically excluded.
IOB_1 can be excluded, but connected peripherals will no
longer be accessible.
Note:
If IOB_1 is excluded, IOR_1 will be automatically excluded.
IOB HubLink All IOB HubLinks can be excluded, but connected
peripherals will no longer be accessible.
Note:
If IOB HubLink_1 is excluded, system disks will no longer be
accessible.
IOR IOR_0 CANNOT be excluded from the domain. The domain
will not power up if IOR_0 is excluded.
IOR_1 can be safely excluded from the domain, but
connected peripherals will no longer be accessible.
QBB At least one QBB must be “included” in the domain.
CPU At least one CPU must be “included” in a QBB.
DPS Only one DPS unit can be safely excluded from the domain
at a given time. At least two DPS units are required to
ensure server operation.
QBB FanBox QBB FanBox_0 CANNOT be excluded.
If QBB FanBox_0 is excluded, QBB_0, IOB_0 and IOR_0
will be automatically excluded. The domain will not power up
if IOB_0 is excluded.
If QBB FanBox_3 is excluded, QBB_3 and IOB_1 will be
automatically excluded. Peripherals connected to IOB_1 will
no longer be accessible.
If QBB FanBox_1 and/or QBB FanBox_2 are excluded,
QBB_1 and/or QBB_2 will be automatically excluded.
SPS FanBox Only one SPS FanBox can be excluded from the domain at
a given time. One SPS FanBox is required to ensure server
operation.
Table 18. Hardware exclusion guidelines