User`s guide
C-28
User’s Guide
Runtime POST Codes
POST Codes Module
0xAFCD IA–32 Intercept Trap due to an unsupported IA–32 instruction
0xAFE8 Normal SAL Machine Check Handling in Progress
0xAFE9 Could Not Correct MC Error, Halting CPU
0xAFEA MCA successfully completed, passing control back to PAL (Resume)
0xAFEB Calling OS MCA for Machine Check error handling
0xAFEC Machine Check Handler Processing Rendezvous Request
0xAFED OS request for SAL Clear Processor/Platform Error/State Log in progress
0xAFEE SAL Platform OEM MCA Error Handler In Control
0xAFEF OS request for SAL Get Processor/Platform Error/State Log in progress
0xAFF0 SAL INIT Handler is in control
0xAFF1 Passing Control to IA–32 OS Init Handler
0xAFF2 Found valid OS_INIT Ep, Passing Control to EM OS Init Handler
0xAFF3 Is a MP platform MCA condition, calling SAL_RENDZ
0xAFF4 Not a MP Platform MCA Init condition
0xAFF5 EM OS with no Init Handler or IA–32OS–BSP detected, Soft Rebooting...
0xAFF6 No OS Initialize Handle Registered, Checking OS Type...
0xAFF8 SAL PMI Handler is in Control
0xAFFA OEM SAL PMI Handler is in Control
0xAFFB Getting Source of PMI Event
0xAFFC Power Management PMI Handler is in Control
0xAFFD Platform Error PMI Handler is in Control
0xAFFE Platform Flash Management PMI Handler is in Control
0xAFFF Platform Emulation PMI Handler is in Control
0xAF71 Recover Reliable Update – verifies the bootblock checksum and corrects if
possible.
Table 55. ACPI POST codes