User`s guide
C-7
Error Messages and Recovery Information
SAL–A Hang POST Codes
POST Codes Meaning
0xDEAD0100 Unable to levelize local RAM
0xDEAD0200 Wrong chip under SNC (neither SPS, nor SIOH)
0xDEAD0300 PEL module not found, local firmware might be corrupted
0xDEAD0400 South Bridge Vendor ID is incorrect, expected ICH2 or ICH4
0xDEAD0500 Scalability Port 0 presence bit is not set
0xDEAD0600 Scalability Port 1 presence bit is not set
0xDEAD0700 Scalability Port 0 framing failed ( Idle Flits Ack. bit is not set )
0xDEAD0800 Scalability Port 1 framing failed ( Idle Flits Ack. bit is not set )
0xDEAD0900 SPS 1 Vendor ID is incorrect
0xDEAD0A00 SPS 1 Vendor ID is incorrect
0xDEAD0B00 No SIOH could be found
0xDEAD0C00 Master IOB not found, at least one IOB should have logical number 0
0xDEAD0D00 Mismatched SPS stepping, expected same stepping for both SPS chips
0xDEAD0E00 Non–transparent Bridge Vendor ID is incorrect, expected 21554 or 21555
0xDEADFF00 CVCR core–to–bus ratio is incorrect, expected 2:8, 2:9, or 2:10
0XDEAD3000 AUTOSCAN module not found, local firmware might be corrupted
0XDEAD3100 Unable to shadow AUTOSCAN module
0XDEAD3200 AUTOSCAN failed
0XDEAD3300 AUTOSCAN Memory Map has too many entries
Table 42. SAL–A hang POST codes (before release B600)