User`s guide
C-20
ESCALA T610 and PL 600T User’s Guide
# Reliable mode
# Echo off
ignore ”0\r” or ”OK\r\n” timeout 2 # Ignore modem response.
send ”AT&E12&E14\r” # Disable pacing
# Disable data compression
expect ”0\r” or ”OK\r\n” timeout 2 # Confirm successful command.
send ”AT&SF1&S0S9=1\r” # DSR independent of CD.
# Force DSR on.
# CD respond time=100ms
expect ”0\r” or ”OK\r\n” timeout 2 # Confirm commands successful.
send ”ATV0S0=0\r” # Numeric response code
# Auto Answer OFF
expect ”0\r” timeout 2 # Confirm commands successful.
done #
error: # Handle unexpected modem
# responses.
expect ”8\r” or ”7\r” or ”6\r” or ”4\r” or ”3\r”
delay 2
done
Sample File modem_m1.cfg
#
# COMPONENT_NAME: (ESPSETUP) ENTRY SERVICE PROCESSOR SETUP modem_m1
#
# FUNCTIONS: Modem configuration file specifically for IBM 7857–017 modem with
# Auto–Reliable feature. This feature must be turned off for Catcher calls.
# This example uses the AT&F reset command to choose the factory defaults.
#
# To allow dial commands for digital pagers, it is necessary to reduce
# the number of characters in the dial command. Each comma (delay) has
# been set to 6 seconds (S8=6) for that reason.
#
#
# (C) COPYRIGHT International Business Machines Corp. 1996
# All Rights Reserved
# Licensed Materials – Property of IBM
#
# US Government Users Restricted Rights – Use, duplication or
# disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
#
ICDelay 1
DefaultTO 10
CallDelay 120
#
# %N Call–Out phone number %R Return phone number
#
#
# PROGRAMMING NOTE: No blanks between double quote marks (”).
condout: send ”AT&F*E0E0\r” # Reset to factory defaults.
# *E0=data compression disabled
# E0=echo disabled
ignore ”0\r” or ”OK\r\n” timeout 2 # Ignore modem response.
send ”AT#F0*Q2S8=6\r” # Trellis modulation disabled
# Retrain with adaptive rate