User`s guide

C-8
ESCALA T610 and PL 600T Users Guide
page: send ”ATDT%N,,,,%R;\r” # %N = pager call center number
# Add enough commas to wait for
# time to enter paging number.
# %R = paging number
# Confirm successful command.
expect ”0\r” timeout 60
delay 2 # Wait before hanging up.
send ”ATH0T\r” # Hang up.
expect ”0\r” timeout 2 # Confirm successful command.
done
ripo: send ”ATZQ0T\r” # Reset to factory defaults.
ignore ”0\r” or ”OK\r\n” timeout 2 # Ignore modem response.
send ”ATE0T\r” # Initialize modem: Echo OFF,
expect ”0\r” or ”OK\r\n” timeout 2 # Enable responses (Numeric),
send ”ATQ0V0T\r” # Limit response codes.
expect ”0\r” timeout 2 # Confirm commands successful.
send ”ATS0=0\r” # Set AutoAnswer OFF
expect ”0\r” timeout 2 # Confirm command successful.
done # RI Power On enabled.
error: # Handle unexpected modem
# responses.
expect ”8\r” or ”7\r” or ”6\r” or ”4\r” or ”3\r”
delay 2
done
Sample File modem_z0.cfg
#
# COMPONENT_NAME: (ESPSETUP) ENTRY SERVICE PROCESSOR SETUP Z0
#
# FUNCTIONS: Modem configuration file for some early Hayes* compatible modems.
# This example uses the ATZ0 reset command to choose the factory defaults.
# This setup is recommended for modems that will respond to the ATZ0 command
# and which do not respond to the extended (&) commands. Refer to your modem
# manual.
#
# * Trademark of Hayes Microcomputer Products, Inc.
#
# (C) COPYRIGHT International Business Machines Corp. 1996
# All Rights Reserved
# Licensed Materials – Property of IBM
#
# US Government Users Restricted Rights – Use, duplication or
# disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
#
#
# If the modem has configuration switches, they should be set to the
# factory default settings.