Installation guide

C-3
PCI Adapters Placement Reference
High–Speed Token Ring
PCI (Type 9–Y)
4959 DCCG135–0000 9, 8, 3, 4, 10, 5, 6, 11, 7, 12 9 Y
10/100 Mbps Ethernet PCI
(Type 9–P)
2968 DCCG137–0000 9, 8, 3, 4, 10, 5, 6, 11, 7, 12 10 (see
notes 3 and
7)
Y
PCI Differential Ultra SCSI
(Type 4–L)
6207 MSCG030–0000 6, 11, 7, 12 10 Y
PCI SCSI–2 Differential
Fast/Wide (Type 4–B)
6209 MSCG032–0000 6, 11, 7, 12 4 Y
POWER GXT120P
(Type 1–P)
2838 GTFG046–0000 6, 11, 7, 12 1 N
PCI SSA Multi–Initiator/
RAID EL (Type 4–N)
6215 6, 11, 7, 12 4 N
PCI Differential Ultra SCSI
(Type 4–L)
6207 MSCG030–0000 9, 8, 3, 4, 10, 5, 6, 11, 7, 12 10 Y
PCI Token–Ring
(Type 9–O)
2920 DCCG136–0000 9, 8, 3, 4, 10, 5, 6, 11, 7, 12 8 Y
PCI Auto LANstreamer To-
ken Ring (Type 8–T)
2979 DCCG104–0000 6, 11, 7, 12 4 Y
PCI SCSI–2 Single Ended
Fast/Wide (Type 4–A)
6208 MSCG031–0000 6, 11, 7, 12 4 Y
PCI 1–port Sync.
Communication Adapter
(Type B2–G)
Bull DCCG097–0000 6, 11, 7, 12 4 Y
PCI 4–port Sync.
Communication Adapter
(Type B2–H)
Bull DCCG098–0000 6, 11, 7, 12 4
(see note 1)
Y
128–Port Async
Controller PCI
(Type B3–9)
Bull DCCG090–0000 9, 8, 3, 4, 10, 5, 6, 11, 7, 12 10
(T610 only)
Y
Notes:
1. Do not connect V35 cables on PCI 4–port Sync.Communication Adapter.
2. For optimum performance using the DC 4961: 10/100 4–Port Ethernet (Type 9–Z) on this
system, use only 2 of the 4 ports if the ports will all be running at media speed. Use a
maximum of six ports per system (that is, three adapters running 2 ports each). Limit
adapters to two per I/O drawer in 64–bit slots.
3. For optimum system performance, the combination of FC 2969: Gigabit Ethernet–SX
PCI (Type 9–U), FC 2741: SysKonnect SK–NET FDDI–LP SAS PCI, FC 2742:
SysKonnect SK–NET FDDI–LP DAS PCI, FC 2743: SysKonnect SK–NET FDDI–UP
SAS PCI, FC 2968: 10/100 Mbps Ethernet Tx PCI (Type 9–P), DC 4951: 10/100 4–Port
Ethernet (Type 9–Z), FC 2963: TURBOWAYS 155 PCI MMF ATM (Type 9–F) adapters
cannot exceed 7 adapters per I/O drawer.
4. For optimum performance, a maximum of 14 FC 2741: SysKonnect SK–NET FDDI–LP
SAS PCI, FC 2742: SysKonnect SK–NET FDDI–LP DAS PCI and FC 2743: SysKonnect
SK–NET FDDI–UP SAS PC adapters per system and a maximum of seven DC 2741, FC
2742, and FC 2743 adapters per I/O drawer is commended.
5. For optimum system performance, a maximum of 7 per system is recommended for both
the FC 2963: TURBOWAYS 155 PCI UTP ATM (Type 9–J) MTU 1500 and FC 2988:
TURBOWAYS 155 PCI MMF ATM (Type 9–F) MTU 1500 adapters.
6. For optimum system performance, a maximum of 16 per system and 7 per I/O drawer is
recommended for both the FC 2963: TURBOWAYS 155 PCI UTP ATM (Type 9–J) MTU