Specifications
Escala Tower PL & S, E, T System Hardware
Chapter 3: External Storage and SAN Subsystems 99/116
9es3s1c3.doc
Rev 5.9
02/12/2003
Power Requirements
Nominal: 100-230 VAC, 47 - 63 Hz
Operational: 85-264 VAC, 47 - 63 Hz
Total Power: 75 watts maximum
Operating Environment
Temperature (operating): 10°C -- 40°C
Temperature (non operating): -35°C - 65°C
Humidity: 5% to 85% non-condensing @ 40°C (104°F)
Altitude: Up to 3,000 m (9,800 ft)
Shock (operating): 4 G, 11 ms, half sine low impulse
Vibration (operating): 5 G, 0-3 kHz
Safety
European Union Market
Compliance with the Low Voltage Directive EEC/73/23 amended by EEC/93/68 and thus to the
following European standards:
•
EN 60950 A4
North American Market
Certified in conformance to UL 1950 3
rd
Ed. (USA) and CSA 950 3
rd
Ed. (Canada), and display the
UL and CSA labels.
Other Countries
•
Certified as conforming to IEC950.
•
TUV, NEMKO
Electromagnetic Compatibility
European Union Market
Compliance with the EMC directive EEC/89/336 amended by EEC/93/68 and thus the following
European Standards:
•
EN55022 Class A
•
EN50082-2 (immunity)
North American Market
Compliance with the following requirements:
•
For USA: FCC part 15 Class A.
•
For Canada: ICES-003 issue 3.
Other Countries
Compliance with the following requirements:
•
Japan: VCCI Class 1 (or A).
•
Rest of the World: CISPR22 class A.