User`s guide
Table Of Contents
- NovaScale 4020 User's Guide
- Preface
- Contents
- 1 System Description
- 2 Board Set Description
- 3 Configuration Software and Utilities
- Utilities / Drivers on Resource CD
- Power-on Sequence and Power-on Self-Test (POST)
- Extensible Firmware Interface Boot Manager
- The Extensible Firmware Interface (EFI) Shell
- BIOS Setup
- LSI Logic* SCSI Utility
- System Maintenance Utility
- EFI Platform Diagnostic Tests
- EFI Service Partition
- Console Redirection
- Terminal Mode
- Shutting Down the Server
- Servicing the System (basic knowledge)
- A Warning and Cautions
- B Working Inside the System
- C Hot-swapping System Components
- D Servicing the Electronics Bay
- Safety Warnings

Board Set Description 27
TP00354
D
C
B
E
A
F
Power bay connector
A. SCSI drive 1 connector B. SCSI drive 2 connector
C. SCSI connector to main board D. Front panel ribbon cable connector
E. Front panel power connector F.
Figure 20. SCSI Backplane Board Layout
QLogic* GEM359* SCSI Hot-swap Controller
The QLogic GEM359 Hot-swap Controller resides on the SCSI backplane board. The primary
functions of the GEM359 are as follows:
• Implements the SAF-TE command set
• Controls the SCSI hard drive fault LEDs
• Provides a path for management information via the SCSI
• Retrieves hard drive fault status, SCSI backplane temperature, and fan failure information
via the IPMB
• Queries the status of the power distribution board by retrieving information from the BMC
via the IPMB
• Controls hard drive power-on and power-down, facilitating hot-swapping