4. When the IML procedure completes (all directors show "0F" in their LED
displays on their front panels), place the operator panel switches (channel
director and disk director) in their enable position.
When "0F" clears from all director LED displays, the CDA 7 is then available
to the host system(s).
A.2 Routinely Powering Down CDA
Perform these steps to power off the CDA 7 using the AC power switch.
1. Stop all processes to the CDA 7.
2. Watch the operator panel and wait for all "Active" LEDs to stop flashing.
NOTE:
The displays stop flashing when the CDA 7 has written all cache data to disk.
3. Press the AC power switch on the rear door to the down (O) position.
NOTE:
The battery backup system automatically turns on when the CDA 7 detects loss
of AC power. The battery will keep the CDA 7 powered for 3 minutes following
which CDA 7 turns off.
A.3 Emergency Powering Down
If it becomes necessary to power off the CDA 7 immediately:
• Press the red EPO switch on the rear door to the down (O) position.
NOTE:
CDA 7 immediately switches to backup battery power and destages any pending
writes in cache to disk. This destage operation takes approximately 20 seconds
following which CDA 7 powers down.
IMPORTANT:
When there is an emergency power cut, data in the cache might not be
saved on the physical disks.