Product manual

Managing Critical Data
77 A1 69UP Rev00 5-9
In summary, dual-initiator provides the following advantages:
Ensures continuous data availability if a CDA 7 disk management component
fails
Provides continuous operation by switching data pathing to the alternate disk
director without interruption when a communications failure occurs with one or
more disk devices
Re-establishes normal data pathing after repair of the defective component
Dual-initiator provides an additional level of data availability in mirrored
configurations. If CDA 7 is unable to read from or write to one of the devices in a
mirrored pair, CDA 7 automatically uses the other disk device in the pair without
interruption. If CDA 7 fails to communicate with that device also, CDA 7 then
attempts to access the volume through the alternate path provided by the dual-
initiator function.
5.2.5 Non-disruptive Component Replacement
CDA 7, with its redundant architecture, supports non-disruptive replacement of
many of its components. This includes online replacement of the directors
(channel directors and disk directors), memory cards, disk devices, adapters
(dual-initiator, serial), power supplies, communications cards, and cooling fans.
This non-disruptive replacement capability allows the Bull Customer Engineer to
install a new component, initialize it if necessary, and bring it online without:
Disrupting access to unaffected volumes
Powering down the CDA 7 unit
Stopping the operating system
Taking unaffected channel paths offline
Taking devices offline (other than the affected device)
This replacement must be done under controlled conditions, please contact your
Bull Competence Center. For a demonstration of non-disruptive component
replacement, contact your Bull Customer Service representative.
NOTE:
When replacing a Director, all activity on the director must be stopped before
attempting this operation.