Datasheet
Technical Information - Switches and Fuseholders
Most major technical information is shown on each specific
product page, other details are grouped here for easy reference.
Details shown here apply to most switches and fuseholders.
Snap-action switches (pages 42, 45 and 48-51), indicators
(pages 66-78) and connectors (pages 79-81) have product
specific information within the section.
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
4
MATERIALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .MOST PRODUCTS. . . . . . . . . EXCEPTIONS
Body and actuator (opaque) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Nylon 6.6 . . . . . . . . . . . . . . . 8300V, 1900V, 0916V & 0911V bezels & actuators
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . are stainless steel
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . 0600 and 3900 actuators are plated brass
Actuator (transparent) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Polycarbonate . . . . . . . . . . .
Current carrying parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Copper Alloy. . . . . . . . . . . . .
Contact points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Silver Alloy. . . . . . . . . . . . . . N/A for 0055/56, 0600/2, 0916-0920, 0017,
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . 2000 & 3005/3006. Gold plated for 1100.
PROPERTIES
Electrical
Class II compliant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Confirmed . . . . . . . . . . . . . . IEC Sockets
Electrical life (Operations) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>10k, many >50k . . . . . . . . See relevant page for details
Contact resistance (switches) new condition . . . . . . . . . . . . . . . . . . . . . .<100mΩ (at 12Vdc,1A) . . . . For 1100 & 2000 call factory
Contact resistance (fuseholders) new condition . . . . . . . . . . . . . . . . . . . .5mΩ (average)
Insulation resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>20mΩ
Dielectric strength:
across open contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>1kV
between poles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>3kV
between live parts and accessible metal . . . . . . . . . . . . . . . . . . . . . .>4kV
Comparative Tracking Index (CTI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>250
Temperature rise (terminals) at end of rated life . . . . . . . . . . . . . . . . . . . .max 30˚K (UL 1054), max 55˚K (EN 61058-1)
PROPERTIES
Physical
Humidity resistance at 91-95% relative humidity
(to subsequently comply with requirements of the
Dielectric strength test) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48hrs
Impact resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>0.5Nm
Storage temp. (1 year period) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<125˚C . . . . . . . . . . . . . . . . . Some discolouration of terminals may occur
Flame retardancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .UL94V2
Solderability to BS 2011 pt.2.1T - (with an iron) . . . . . . . . . . . . . . . . . . . .6 secs at 350°C
Angular movement ± 4° overall (where applicable) . . . . . . . . . . . . . . . . .38°. . . . . . . . . . . . . . . . . . . . 1250, 6000, 8500, 8550, 8600, 8650, 8800 - 26°
Force to operate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.0N - 20.0N . . . . . . . . . . . . Call factory for specific values
Fixing nut torque (where applicable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.0Nm (8.91 lb/in) nom.. . . . Call factory for specific values