Instructions

Buccaneer
®
IP68 & IP69 Waterproof Connectors
Wiring and Assembly Instructions
PANEL CUT-OUTS
FRONT PANEL MOUNTING REAR PANEL MOUNTING
BULKHEAD/SURFACE MOUNTING
SEALING CAP/ASSEMBLY TOOL
Assembly Instructions Buccaneer R.F. Insert (BNC Compatible)
For use with cables:
50Ω - URM 76, URM 43, RG58c/u.
75Ω - URM 70.
Crimp Tool - Hex Cavities,
C
entre Contact 1.69 A/F (B.S. ‘W’/ERMA XA.)
Braid 6.48 A/F (B.S. ‘E’/ERMA XH.)
1 Flex Mount
F
it gland nut, washer, gland & main body loosely over cable, followed by BNC
p
lug/jack metal body.
C
hassis/Bulkhead
F
it main body to chassis/bulkhead, ensuring sealing washer(s) are in position.
Then assemble BNC plug/jack body to cable.
2 Crimp centre contact onto cable centre conductor (butting to cable inner
insulator).
3 Slide knurled ferrule over contact & cable inner insulator & under cable braid.
4 Snap-Fit insulator over centre contact (support insulator with assembly
mandrel, or against hard surface).
5 Push body over assembly, pressing insulator, until ferrule bottoms in body.
(SA3155 assembly mandrel is available to aid assembly if required).
6 Crimp body to secure cable braid.
7 Lock BNC body flange into main body using locking ring. Ensure correct
alignment of flat.
8 At cable entry, seat gland & washer, tighten gland nut to seal (for
flex mount).
CABLE TRIM & PIECE PARTS
FLEX MOUNTING
IN-LINE CO-AXIAL CABLE
CONNECTOR
F
LEX MOUNTING
C
O-AXIAL CABLE
C
ONNECTOR
bu lgin
a brand of Elektron Technology
bulgin.com