Datasheet

30 Circular Power Connectors
BUCCANEER FOR POWER
PX0777 WIRING AND ASSEMBLY INSTRUCTIONS
Strip wires to dimensions shown.1.
Assemble components parts onto cable as
shown, then connect wires to terminal block.
ENSURING WIRES CONNECTED INTO ONE SIDE
OF TERMINAL BLOCK MATCH WIRES CONNECTED
INTO THE OTHER SIDE.
i.e. Brown to Brown (Live)
Blue to Blue (Neutral)
Green/Yellow to Green/Yellow (Earth)
2.
Wire stripping details
Bring the two body mouldings together ensuring the ‘O’
ring is correctly located in groove then lock together with
locking ring, ensure ring is fully tightened.
Put gland cage over gland and push fully home into its
appropriate body then fully tighten gland nuts.
3.
To ensure a good seal, all surfaces must be completely
free of dust, grease or any other contamination.
4.
THIS CABLE CONNECTOR IS SUITABLE FOR
USE WITH LOADS NOTEXCEEDING 16 AMPS
USING 1.5mm2 CABLE
ALWAYS USE WITH SUPPLY PROTECTED BY
AN RCD, IF IN DOUBT CONSULT A QUALIFIED
ELECTRICIAN.
DANGER
DISCONNECT MAINS
SUPPLY BEFORE
DISMANTLING
CONNECTOR