Specifications
Chapter 5 Function Parameter Simple List VFD‐G7 Series Frequency Inverter Operation Manual
89
Function
Code
Name
Setting Scope and
Introduction
Factory
Defaults
Modify Page
rated power
FF.31
Frequency inverter
rated voltage
Model confirm ○ 154
FF.32
Frequency inverter
rated current
Model confirm ○ 154
FF.33
Frequency inverter
type
0:G type
1:P type
○ 155
FF.34
Output upper-limit
frequency
Unit: 0.01Hz ○ 155
FF.35
VR potentiometer
input percentage
0.0~100.0% ○ 155
FF.36
Analog V1
corresponding
percentage
-100.0~100.0% ○ 155
FF.37
Analog V2
corresponding
percentage
-100.0~100.0% ○ 155
FF.38
Rapid pulse input
corresponding
percentage
-100.0~100.0% ○ 155
FF.39
Analog output
FM1
corresponding
percentage
0.0~100.0% ○ 155
FF.40
Analog output
FM2
0.0~100.0% ○ 155