Specifications
Chapter 5 Function Parameter Simple List VFD‐G7 Series Frequency Inverter Operation Manual
59
Function
Code
Name
Setting Scope and
Introduction
Factory
Defaults
Modify Page
F3.17
Choice of torque
setting mode
0: Keypad digital
frequency setting
1:Analogue V1 setting
2:Analogue V2 setting
3: Keypad potentiometer
setting
4: Telecommunication
setting
0 √ 118
F3.18
Keypad digital
torque setting
-100.0~100.0%
( 100.0% the
corresponding torque
upper-limit)
50.0% √
118
F3.19
The source of
setting upper limit
frequency selection
0: Keypad sets
upper-limit
frequency(F0.06)
1: Analog V1 sets
upper-limit frequency
2: Analog V2 sets
upper-limit frequency
3: Telecommunication
sets upper-limit frequency
0 √ 118
F4:Input Signal Group
F4.00
S1 terminal
function selection
00: No function
01: Forward
02: Reverse
03: 3-wire operation
1 × 119
F4.01
S2 terminal
function selection
2 × 119