Specifications
VFD‐G7SeriesFrequencyInverterOperationManualChapter5FunctionParameterSimpleList
54
Function
Code
Name
Setting Scope and
Introduction
Factory
Defaults
Modify Page
in keyboard control
0:No restart
1:Allow auto-restart
F1.01
Directly start
frequency
0.00~10.00Hz 0.00Hz √ 107
F1.02
Start frequency
holding time
0.0~50.0s 0.0s √ 107
F1.03
DC braking current
at start
0.0~150.0% 0.0% √ 107
F1.04
DC braking time at
start
0.0~50.0s 0.0s √ 107
F1.05
Stopping function
selection
The single digit:stopping
mode choice
0: Dec to stop
1: Coast to stop
Tens: stopping DC
braking use enabled
0:Disable
1: Enable, DC braking
start frequency decided by
F1.06
2: Enable, DC braking
start frequency decided by
external terminal
0010H × 108
F1.06
Stopping braking
start frequency
0.00 Hz~ F0.05 0.00Hz √ 108