Specifications

Chapter 5 Function Parameter Simple List VFDG7 Series Frequency Inverter Operation Manual
53
Function
Code
Name
Setting Scope and
Introduction
Factory
Defaults
Modify Page
F0.25
Holding time of
zero frequency
runtime output
voltage
0.06553.5s 3600.0s 105
F0.26 Software version 105
F0.27
Parameter
initialization
0No-operation
1: Recover the factory
settings
2: Clear the fault record
0 × 105
F1 group: Start/stop Control Parameter Group
F1.00
Start function
choice
The single digit start
mode selection
0: Direct-on starting
1: DC braking first, then
start
DecadeReserve
Hundreds: Terminal
control, restart choice
when power-off
0: The terminal operation
command is invalid when
power-on
1: The terminal operation
command is valid when
power-on
Thousands: Restart
selection after power cut
0000H × 105