Specifications

VFDG7SeriesFrequencyInverterOperationManualChapter4KeyboardOperationandDisplay
44
In the Third level menu state, if the parameter is without flash bit, it indicates that the
functioncodecouldn’tbemodified,itmaybecausedbythefollowingreasons:
1) The function code is non-modifiable parameter, such as actual monitoring parameter
and run recording parameter and so on.
2) The function code is in the process of running, it couldn’t be modified and only
could be modified after stop.
The operation panel can do a lot of operations, such as: set the parameters, reset the
faults, auto-learn the motors parameters, set the password, display the running state and
so on, we would introduce all kinds of operation method and procedure in the following.
4.4 Checking Method of State Parameter
The user could select the stop normal monitoring variable by setting F9.01 and select the
running normal monitoring variable by setting F9.02. When the frequency inverter is
powered after the power failure, the shown parameter is defaulted as the selected
parameterbeforepowerfailure.
In the stop or run state, the
following 6 variables could be shown in cycle by the shift
key >>/SHIFT : run frequency (Hz light is flash), setting frequency (Hz light is on), busbar
voltage,outputcurrent,outputvoltage,runningrotatespeed.
TheFFgroupparameteristherealtimemonitoringvariablegroup,whichisusedtodisplay
thevalueofthecorrespondingvariableinrealtime.
Ifthere
isnoanypressingkeywithinoneminute,itwouldbebacktothenormalmonitoring
interface.
4.5 Password Setup
Thefrequencyinverteriswiththeuserpasswordprotectionfunction,whentheF9.03isnot
zero,theuserpasswordsettingisvalid,1minuteafterexitingthefunctioncodeeditingstate,
50. 00 F0
MODE
F3 F3. 00
ENTER
F3. 14
10. 0010. 0012. 00F3. 15F3
>>/ SHIFT
ENTERMODE
MODE
ENTER