Specifications
VFD‐G7SeriesFrequencyInverterOperationManualChapter3MechanicalandElectricalInstallation
24
Chapter 3 Mechanical and Electrical Installation
Warning
In order to ensure the safe and reliable running and operation of the products, the
frequencyinvertermustbeproperlyinstalledandoperatedundertheguidanceofqualified
personnel .And pay special attention to the work codes and specifications of the
high‐voltage.
3.1 Mechanical Installation
3.1.1 Installation Environment
1) Ambient temperature: The surrounding environment and temperature has great
influence on the life of the frequency inverter, the running ambient temperature of the
frequencyinvertershouldbewithinthetemperaturerangeof‐10℃~50℃.
2) The frequency inverter should be installed on the surface of the antiflamming goods,
there
mustbeenoughspaceforheatdissipationaround,installtheinverterverticallyonthe
supportwiththescrew.
3)Installinthelocationwherevibrationislessthan0.6G,Payspecialattentiontobeaway
fromthepunchpressandotherequipments.
4)Installinthelocationfreeofdirect
sunlight,wet,dropsofwater.
5)InstallinthelocationReserveawayfromcorrosivegas,Flammablegaseorexplosivegas.
6)Installinthelocationavoidgreasydirt,dust,metaldust.
3.1.2 Installation Space
!
VFD-G7
≧100mm
A A
VFD-G7