Specifications
 Chapter2SpecificationsandSelectionVFD‐G7SeriesFrequencyInverterOperationManual
11
Torque control 
precision 
Open-loop vector control: ±5% 
Torque response 
time 
Open-loop vector control: <20ms 
Function  Channel of operation 
command 
Keyboard control , terminal control ,
communication control 
Start mode  Direct start, DC injection braking before start, 
speed tracking before start 
DC injection braking  Start DC injection braking, stop DC injection 
braking 
Dynamic braking  Built-in braking unit < = 11kw, get external 
braking unit>15kw 
Frequency source 
choice 
Keyboard digital frequency setting, analog 
V1 setting, analog V2 setting, Keyboard 
potentiometers setting, Multiple speed 
operation setting, 
PID control setting, telecommunications 
setting, PLC program operation setting, HDI 
High Speed Pulse setting 
Main and auxiliary 
frequency 
combination set 
Just main frequency setting, just auxiliary 
frequency setting, QUICK/JOG or terminal 
switching selection, main frequency + 
auxiliary frequency, main frequency - 
auxiliary frequency, maximum, minimum, 
could realize 
Frequency overlay and fine adjustment 
function 
Frequency resolution Keypad setting:0.01Hz; Analog setting: 0.1% 