Specifications
 Chapter6FunctionalParameterDetailVFD‐G7SeriesFrequencyInverterOperationManual
144
FA.08 
Traverse 
operating 
amplitude 
Default: 0.0%
Setting scope: 0.0~100.0%(relative setting 
frequency) 
FA.09 
Jitter frequency
amplitude 
Default: 0.0%
Setting scope: 0.0 ~ 50.0% ( relative 
traverse amplitude) 
FA.10 
Rising time o
f
Traverse 
operating 
Default: 5.0s 
Setting scope:0.1~3600.0s 
FA.11 
Dropping time o
f
traverse 
operating 
Default: 5.0s 
Setting scope:0.1~3600.0s 
Traversefunctioniswidelyused intextileandchemicalfiberandthesituation whereneed
traverseandwindingfunction.
Traverse function is that the output frequency of drive will bob up and down for the
reference frequency as the center. The locus of traverse frequency with time is shown in
fig.6
‐19, in which FA.08 is the reference value of traverse operating amplitude, when the
FA.08is setto 0,meaningisthetraverse operatingamplitude is0,thetraverse functionis
invalid.
Figure 6-19 Illustration of traverse run 