Specifications
VFD‐G7SeriesFrequencyInverterOperationManualChapter2SpecificationsandSelection
10
2.4 Technical Specification 
Table2‐2SVF‐G7FrequencyInverterTechnicalSpecifications
Item Specification 
Input  Rated voltage  T4 series: Three phase 380v, ±15% 
Frequency  50/60Hz ±5% 
Output  Voltage  Three phase 0-380V 
Frequency 0-600Hz 
Overload ability  Type G: 150% rated current for 1 minute, 
180% rated current for 2 second; 
Type P: 120% rated current for 1 minute, 
150% rated current for 2 second. 
Heat 
Dissipation 
Cooling type  Forced Cooling 
Temperature 
protection 
Heatsink temperature >85℃ trip protection 
against overheat 
Fan control 
Heatsink temperature> 50℃, fan forced 
operation, frequency inverter continue work 
Control 
Performance 
Control mode 
Open-loop vector control, V/F control, 
Torque Control 
Start torque  Open-loop vector control: 0.5Hz 180%; 
VF control:0.5Hz 150% 
Speed range  Open-loop vector control: 1:200; 
VF control:1:100 
Speed control 
precision 
Open-loop vector control: ±0.2%; 
VF control:±0.5% 