Specifications

Chapter6FunctionalParameterDetailVFDG7SeriesFrequencyInverterOperationManual
132
Figure 6-15 Illustration of Simple PLC Run
The corresponding max frequency is F0.05 if the frequency is set to 100.0%, the minus
indicatesruninreverse.
The relation between the state that multifunction input terminal select multispeed
terminal 4,3,2,1 and segments number of multispeed and selected goal setting is as the
following table. 0 represent
the terminal disconnect of the corresponding function, 1
representtheterminalcloseofthecorrespondingfunction.
Terminal 4 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
Terminal 3 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1
Terminal 2 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1
Terminal 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1
Segments number 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Goal setting F6.
00
F6.
01
F6.
02
F6.
03
F6.
04
F6.
05
F6.
06
F6.
07
F6.
08
F6.
09
F6.
10
F6.
11
F6.
12
F6.
13
F6.
14
F6.
15
F6.32 PLC function selection
Default: 0000H
Setting scope0000H1122H
...
SP1¡ ¢ SP2¡ ¢ T 1
F6 . 00
F6. 0 1
F6. 0 2
F6. 1 5
F6. 1 6
st age 0
F6. 1 8
st age 2
F6 . 17
st age 1
out put f r equency
500ms pul se