Specifications

VFDG7 Series Frequency Inverter Operation ManualChapter 6 Functional Parameter Detail
127
voltageoutputcouldbeselectedthroughJP9andJP10jumpers.The outputrangeofHDO
ofopencollectorhighspeedpulseis0.050.0kHz.
Notes:TheoutputofHDOofopencollectorhighspeedpulseisonlyvalidinVFcontrolmode
(F0.014=1).
The representative corresponding variable range is as follows:
Set value Function Range
0 Running frequency 0max output frequency
1 Setting frequency 0max output frequency
2 Busbar voltage 02 times standard busbar
3 Output current 02 times frequency inverter rated current
4 Output voltage 01.5 times frequency inverter rated voltage
5 Running speed 03 times motor rated speed
6 Output power 02 times motor rated power
7 Setting torque 02 times frequency inverter rated current
8 Output torque 02 times frequency inverter rated current
9 PID setting 0.0100.0%
10 PID feedback 0.0100.0%
11 Analog V1 input value 0.010.0V
12 Analog V2 input value 0.010.0V/ 020mA
13 HDI high speed pulse
input frequency
0.050.00kHz
14 Retain
15 Retain