Specifications

Chapter6FunctionalParameterDetailVFDG7SeriesFrequencyInverterOperationManual
126
followingfigure613:
Figure 6-13 Illustration of FDT electrical level
F5.16 FDT Torque level detection value Default: 100.0%
Setting scope 0.0
250.0%
F5.17
FDT Torque level detection lagged
value
Default: 5.0%
Setting scope: 0.0
100.0%
When output current percent is equal or greater than F5.16, the corresponding
multifunctioninputterminalisclose, whenoutputcurrent percentislessthanor equalto
F5.16*(1000‐ F5.17) again, then the terminal breaks. It is similar with FDT electrical level
function.
Terminal output will break unconditionally in stop or fault state.
F5.18 FM1 output selection Default: 0
Setting scope015
F5.19 FM2 output selection Default: 3
Setting scope015
F5.20 HDO high speed pulse output selection Default: 1
Setting scope015
The standard output of FM1 and FM2 analog output is 010V or 020mA, current or