Specifications

VFDG7 Series Frequency Inverter Operation ManualChapter 6 Functional Parameter Detail
125
F5.12
Relay1 TABC output break delay
time
Default: 0.0s
Setting scope: 0.0
6553.5s
Set SP1, SP2 and relay 1, the delay time from the change of state to the change of actual
output.
F5.13
Frequency arrival (FAR)
detection width
Default: 0.0%
Setting scope 0.0100.0%
(max output frequency)
The output frequency of frequency inverter output pulse signal in the positive and
negative detection width of setting frequency, the detail is as the following figure 6-12.
Figure 6-12 Illustration of the frequency arriving at the detection amplitude
F5.14
FDT electrical detection
value
Default: 50.00Hz
Setting scope00.00F0.05
F5.15 FDT lag detection value Default: 5.0%
Setting scope000.0100.0%
(FDT electrical level)
ONsignalisoutputwhenoutputfrequencyexceedsasettingfrequencyFDTelectricallevel
untiltheoutputfrequencyislowerthanF5.14*1000‐F5.15),thedetailwaveformisasthe