VFD‐G7 Series Frequency Inverter Operation ManualChapter 6 Functional Parameter Detail
123
F5.05 Relay 4 output selection Default: 0
F5.06 Relay 5 output selection Default: 0
0:Nooutput
1:Frequencyinverterinservice
Whenthefrequencyinverterruns,ONsignalisoutput.
2:Frequencyinverterisready
Whenfrequencyinverterisinhaltmodeandwithoutfault,ONsignalisoutput.
3:Frequencyinverterisinfault
Whenfaulthappenstofrequencyinverter,ONsignalis
output.
4:FrequencyleveldetectsFDToutput.
5:Setfrequencyarrival
6:Zerospeedinservice
Whentheoutputfrequencyis0,ONsignalisoutput.
7:Upperlimitfrequencyarrival
Whenrunningfrequencyarrivesupperlimitfrequency,ONsignalisoutput.
8:Lowerlimitfrequencyarrival
Whenrunningfrequency
arriveslowerlimitfrequency,ONsignalisoutput.
09:OutputisfinishedduringPLCprogramrunningstage
A500mswidthpulsesignalisoutputwhenPLCprogramrunfinishesastage.
10:OutputisfinishedduringPLCprogramcirculating
A 500ms width pulse signal is output when PLC program run
finishes a circulation this
functionisinvalidifitissettocontinuouscycle.
11:DCbrakinginprocess
12:TorqueleveldetectsFDToutput
13:Retain
14:Retain
15:Runinreverse
16:Retain