Specifications
 Chapter6FunctionalParameterDetailVFD‐G7SeriesFrequencyInverterOperationManual
120
currenteffectiveAcc/Dectime;
24:Selectionoftheauxiliaryfrequencysource
Whentheterminalwith functionis setto close,the auxiliaryfrequencysourceselected by
F0.03isregardedasvalidreferencefrequency.
Notes: this function is prior to the main and auxiliary frequency source switch set by
QUICK/JOG.
25:Pause
thesimplePLCprogramoperation
26:Reserve
27: Reserve 
28: Stop DC braking control   
29: Reserve   
30: Reserve 
 F4.10  Filter times of the switch  Default: 5 
Setting scope: 0~10 
The parameter is used to set the filter time of S1~S10 terminals’ sampling. In the case of
largedisturbance,theparametershouldbeincreasedtoavoidmalfunction
F4.11 Lower  limit  of  V1 
Default:0.00v Setting scope: 0.00~F4.13
F4.12 
The reference percent
corresponding to lower limit
of V1 
Default:0.0% 
Setting scope : -100.0 ~
100.0% 
F4.13 Upper  limit  of  V1 
Default:10.00V
Setting scope : F4.11 ~
10.00V 
F4.14 
The reference percent
corresponding to upper limit o
f
V1 
Default:100.0%
Setting scope : -100.0 ~
100.0% 
F4.15 Filter time of input V1 
Default:0.10s Setting scope:0.00~10.00s
The above function code defines the relationship between the analog input voltage’s and