F2.09 Custom V/F percentage Default: 100.0%
Setting scope50.0100.0%
F2.10 V/F slip compensation gain Default: 0.0%
Setting scope0.0200.0%
SettingthisparametercouldcompensatethemotorspeedchangecausedbytheloadinV/F
control, which can improve the hardness of motor mechanical characteristics, this value is
correspondingtothemotor’sratedslipfrequency.
F2.11 Suppress oscillation enabled Default: 1
Setting scope01
0:Suppressoscillationvalid
1:Suppressoscillationinvalid
The function code of suppression oscillation is for V/F control, the common motor with
noload or lightload often has current oscillation to leadthe motor’s abnormal operation,
theseriouscan cause drive over current.When the F2.11 is selected to 0,
the suppressing
oscillation function is enabled, the drive will suppress the motor’s occurring oscillation
accordingtotheparametersoffunctionsF2.12F2.15.
F2.12
Suppress oscillation low-frequency
threshold
Default5 Setting scope0500
F2.13
Suppress oscillation low-frequency
threshold
Default100 Setting scope0500
Whenmostofmotorsruninsomefrequencyband,thecurrentoscillationwilleasilyoccur,
lightcaseis thatthemotor cannotstable operate,theserious situationwillleadthedrive
overcurrent.
When F2.11 is set to 0, suppress oscillation is valid. When F2.12 and F2.13 have small
reference
values, the effect of the suppress oscillation is evidence, the addition of the
currentisevidence;ifthesettingsislarge,theeffectofsuppressoscillationisweak.
F2.14
Amplitude limit of suppress
oscillation
Default: 5000
Setting scope010000