Specifications

Chapter6FunctionalParameterDetailVFDG7SeriesFrequencyInverterOperationManual
102
Carrier
Frequency
Motor temperature rising
Output current smoothness
Temperature rise of frequency
inverter
Leakage current
External radiated interface
The relation between machine type and carrier frequency is as the following table:
Carrier
Frequency
machine type
Max Carrier
Frequency
(kHz)
Min
Frequency
(kHz)
Default
(kHz)
0.7511kW
15.0 0.5 4.0
1555kW
8.0 0.5 3.0
75400kW
6.0 0.5 2.0
Whenthe outputfrequency of frequency inverter is 0Hz, and it is in vector control or V/F
control and torque lift, there is the voltage output in the frequency inverter, if running in
0Hzinalongtermandthereisvoltageoutput,themotorheatdissipationisbad,itis
easyto
cause the motor heating. The user could set a certain output voltage holding time, after
exceeding this holding time, the output voltage will turn to 0, which could prevent the
motorfromoverheating.
F0.23
Voltage of energy
consumption brake value
Default130.0%380V
series
120.0% 220V
series
Setting Range:115.0
140.0%(Standard
bus-wire voltage
Thisfunctioncodeisthestartvoltageofsettingenergyconsumptionbrakingunit,ifweset
thisvalueproperly,whichcouldbraketheoverloadeffectively.
F0.24
Given frequency is less than frequency
lower limit
Default0 Setting Range02
0Operatingtolowerlimitfrequency