Specifications
 Chapter6FunctionalParameterDetailVFD‐G7SeriesFrequencyInverterOperationManual
100
1: Storage when powering down 
The setting frequency will be stored when the frequency inverter is powered down. When 
the power is on, it will combine with the current setting frequency automatically. 
Hundred 
0:Zeroclearingwhenstop
The、keysonthekeyboardandUP/DOWNterminalfunctionarevalidintheprocessof
running,automaticzeroclearingissetwhenstopping.
1:Nozeroclearingwhenstop
The、keysonthekeyboardandUP/DOWNterminalfunctionarevalidwhenrunning
and
stopping.
Notes:Whentheuser performsrecoverdefault valueoperation tothefunctionparameter
ofthefrequency inverter,thesetting of keyboardandUP/DOWN terminal functionwill be
zeroclearingautomatically.
The rate of change when adjusting and setting frequency of the keys ▲、▼ on the 
keyboard and UP/DOWN terminals. 
F0.21 Modulation  function selection  Default: 0000H
Setting scope: 0000H~
1111H 
Unit Digit AVR 
0:Invalid
1:Validforwholecourse
2:Onlyinvalidfordeceleration
AVRfunctionisoutputvoltageautomaticadjustmentfunction.WhenAVRfunctionisinvalid,
the output voltage will vary with the input voltage (or DC busbar voltage); when the AVR
function is valid, the output voltage will not vary with
 the input voltage (or DC busbar
voltage),theoutputvoltagewillReserveconstantwithintheoutputabilityscope.Whenthe
deceleration time is too long to meet the on site requirement, the AVR function could be
F0.20 
UP/DOWN change
rate 
Default:1.00 
Hz/s 
Setting scope:0.01~100.00Hz/s 