User's Manual

S3-915M User manual
22
OK
Precautions
Command
character
Command
Type
Command Format
response
CNBTRIALS
(Set the number
of times to send)
Test
command
AT+CNBTRIALS=?
+CNBTRIALS: MType,value
OK
Query
command
AT+CNBTRIALS?
+CNBTRIALS:<MType>,<value>
OK
Setting
command
AT+CNBTRIALS=<MType>,
<value>
OK
Parameter
Description
<MType>:0:unconfirm 包, 1:confirm 包。
<value>the maximum number of times to send, value range: 1~15;
Return value
description
Example
AT+CNBTRIALS=1,2
OK
Precautions
Need to set before sending data
Command
character
Command
Type
Command Format
response
CRM
(Set reporting
mode)
Test
command
AT+CRM=?
+CRM:reportMode,reportInterval
OK
Query
command
AT+CRM?
+CTXP:<reportMode>,[reportInterval]
OK
Setting
command
AT+CTXP=<reportMode>,[re
portInterval]
OK
Parameter
Description
<reportMode>
0- acyclic reporting data;
1- Periodic reporting of data;
<reportInterval> This parameter is only available when data is reported
periodically. Time interval of periodic report data, unit: s.For different Dr's,
the minimum period allowed is different. The definition of period level is
adopted, as shown in the following table.
Rate\cycle(s)\level LV1 LV2
DR0 150 300
DR1 75 150
DR2 35 70
DR3 15 30
DR4 10 20
DR5 5 10
Return value