User's Manual

S3-915M User manual
21
Command
character
Command
Type
Command Format
response
CDATARATE
(Set the
communication
rate)
Test
command
AT+CDATARATE=?
+CDATARATE:value
OK
Query
command
AT+CDATARATE?
+CDATARATE:<value>
OK
Setting
command
AT+CDATARATE =<value>
OK
Parameter
Description
<value> as follows:
Rate value, the factory value is 3, the value range:
0 - SF12 BW125
1 - SF11 BW125
2 - SF10 BW125
3 - SF9 BW125
4 - SF8 BW125
5 - SF7 BW125
Return value
description
Example
AT+CDATARATE=1
OK
Precautions
Need to be set before sending data, invalid after ADR is enabled.