Operator`s manual
18
\
4. On the front of the implement valve assembly
unsnap the flow control cables, 1, from the
bellcrank, 2.
NOTE: 80 series tractors will have one flow control
cable standard. 82 series tractors can have one flow
control cable or an optional four flow control cables.
84/2000Series tractors have four flowcontrolcables
as standard equipment as shown.
1
2
41
5. Removetheimplementvalvefromtherearframe
ofthetractorbyremovingthetwocapscrewsand
lock nuts, 1. Retain the hardware for reinstalla-
tion. Tilt the valve stack up to the right and place
a block of wood under the valve assembly.
NOTE: Note the bolt hole location where the
implement valve assembly was mounted to the rear
frame. There are three possible locations depending
on the series of tractors and number of flow control
cables.
10000643
1
1
42
6. From the right hand side (inlet end) of the
implementvalve removethe nutandlock washer
from the top center through bolt.
7. Gentlypullthetopthroughbolt,1,outofthevalve
stack towards the left (outlet) side of the tractor.
10000644
1
43