Alert Sound Settings
Click Modify Settings to
change settings.
Alert Sound Settings Beep alerts can be triggered by the following conditions : Overheating, Disk
Error, Fan Error, and UPS power Error.
Front Panel Settings
Click Modify Settings to
change settings.
Display Select items to display on LCD display at the front of the TeraStation from Host
IP, Disk Mode, and Time.
Flip Display Items Set if automatically switching the item to display on the LCD or not.
LCD brightness Adjust backlight brightness of the LCD display in 5 levels.
LED brightness Adjust the brightness at the front of the TeraStation in 5 levels.
LED Synchronization Select whether using the feature to change the LED brightness synchronized
with time. For example, you can change the brightness on day time and night
time.
LED brightness (Sleep) Adjust the brightness of LED in 4 levels while in dark.
Begin Sleep Set the time (0 to 23 o’clock) to darken LED brightness. This can be set in every
00 minute at 1 hour interval.
Wakeup Set the time (0 to 23 o’clock) to change LED brightness back to the normal
setting. This can be set in every 00 minute at 1 hour interval.
Firmware Installation
Clicking Check For Update will check for the latest rmware version.
If the installed rmware version is not the latest, click Install Update to update
the rmware.
Update notication will display “I52” on the LCD and a message on the login
screen when an update is available. To disable update notication, click
Disable notication of updates.
Power Management
UPS Settings
Click Modify Settings to
change settings.
Synchronization with
UPS
synchronize with UPS connected to this TeraStation:
Select to synchronize the TeraStation with a UPS that is directly connected.
synchronize with UPS connected to other TeraStation on the network:
Select to synchronize the TeraStation with a UPS that is connected to a
dierent TeraStation on the same network.
do not synchronize with UPS:
Select if synchronizing to a UPS is not desired.
Synchronized source
TeraStation IP Address
If synchronize with UPS connected to other TeraStation on the network is
selected, enter the IP address of the TeraStation that is directly connected to
the UPS.
UPS Connection Type Select a connection method for the UPS.
USB Port (APC Style) or USB Port (OMRON Style) can be set only when you are
using USB type UPS manufactured by APC.
TeraStation behavior
When Power failure
You may set how long the TeraStation runs after a power failure before it
shuts down. Or, you can set it to shut down when the UPS signals Battery Low.
“Low Battery“ shutdown is only supported with UPSs that are connected to
the TeraStation via USB. You can also set the TeraStation to shut down when
the number of iSCSI connections becomes 0 (zero).
UPS Behavior After
TeraStation has shut
down
You may also select to have the UPS shut down after the TeraStation shuts
down.
UPS Recovery function Enable to have the TeraStation reboot automatically when normal AC power
is restored.
Restart TeraStation
Restart Click Restart to reboot the TeraStation.
Shutdown TeraStation
Shutdown Click Shut Down to turn o the TeraStation. To turn it back on, press the power
button on the front of the unit.