User manual

TeraStation III iSCSI User Manual 32
Examples:
These emails are for example only. Your notication emails may be dierent.
This email includes HDD Status Report:
TeraStation Status Report: Periodical Report: Information
TeraStation Information
TeraStation Name: TS-xxxxx
Time Stamp: 2009/03/23 00:00:01
IP Address: 172.16.37.62
Conguration Screen: http://172.16.37.62/
Continuous operating time: 13:51:57
This email includes Disk Error:
TeraStation Status Report: DISK Error Notication: Failure: Fail to mount a disk
DISK Error Notication
The error occurred on HDD.
The erroneous disk drive: Disk 1
Disk could not be mounted.
This email includes Fan Failure:
TeraStation Status Report: FAN Error Notication: Failure: FAN stopped.
FAN Error Notication
The FAN has stopped.
The internal temperature is now over the threshold. Shut down the system.
System temperature: 52 [
°C
]
9 Select the conditions to send.
HDD Status Report Current status of the hard drives at the specied time.
Fan Failure When a fan failure occurs.
Disk Error When a hard drive error occurs.
System Alert When the TeraStation is rebooted or shut down. Also when current RAID
conguration is changed.
10 If you have selected HDD Status Report for sending condition, select time to send.
11 Click Save.
You have congured email alerts.