Errors and Warnings
Displays the current status when changing the settings or formatting drives.
Examples of LCD Meaning
SYSTEM Error E00
MPU No Response
The system is not responding. Disconnect power for 10 seconds, then
reattach and boot the TeraStation. If the error persists, contact tech
support.
DRAM LINES E01
DATA Failure
IC error. Contact tech support.
DRAM LINES E02
ADDRESS Failure
IC error. Contact tech support.
RTC Chip E03
No RTC Clock
Clock error. Disconnect power for 10 seconds, then reattach and boot the
TeraStation. If the error persists, contact tech support.
SYSTEM Error E04
Can't Load Krnl!
The rmware is corrupted. Contact tech support for assistance.
WDT E05
SYSTEM Stopped
System hung. Disconnect power for 10 seconds, then reattach and boot
the TeraStation. If the error persists, contact tech support.
TFTP MODE E06
Lost boot image
The rmware is corrupted. Wait for 5 minutes. If "E04" appears on the
display, turn off the unit. Contact tech support for assistance.
HD ALL
E07
ALL HD Not Found
Hard disks are not found. If the drives are installed but this message
appears, contact Buffalo’s tech support for assistance.
UPS          E10
Dependent Mode
Power outage. The TeraStation is running on UPS battery power and will
be shut down safely.
SYSTEM I10
TOO HOT!
System temperature is above safe limits. Move the TeraStation to a cooler
place. Do not place anything too close to the Terastation that might block
airow.
SYSTEM Error E11
Fan Failure
The fan is not spinning. Check for dirt or objects caught in fan. Remove
any debris with tweezers or canned air. If the error persists, contact tech
support.
SYSTEM Error E12
Cooling Failure
System temperature is above safe limits. Move the TeraStation to a cooler
place. Do not place anything too close to the Terastation that might block
airow.
RAID Error E13
ARRAYx Error
An error has occurred in the Xth RAID array. The system will run in
degraded mode if RAID1 or RAID5 is used. For best results, test the drives
individually and replace the defective drive.
RAID Arrayx E14
Can't Mount
The Xth RAID array could not be mounted. Turn off the TeraStation, then
reboot it. If the error persists, rebuild the RAID array. If the error still
persists, contact Buffalo’s tech support for assistance.
HDx Error E15
Many Bad Sectors
The bad sectors in the Xth hard drive have become serious. Replace the
drive.
HDx Error E16
HDx Not Found
Cannot nd the Xth hard drive. The Xth hard drive may not be connected or
may be damaged. Check the drive and replace if necessary.