User manual

TeraStation IS Setup Guide 57
Status
Displays the current status when changing the settings or formatting drives.
Display Meaning
HDx Warning I11
Bad Sectors
The bad sectors in the Xth hard drive are serious. Replace the Xth hard drive.
OperationModeI12
DEGRADE MODE
The RAID array is running in degraded mode.
RAID I13
ARRAYx Formatting
Formatting the Xth RAID array.
RAID I14
ARRAYx Checking
Checking the Xth RAID array.
RAID I15
ARRAYx Scanning
Scanning the Xth RAID array. Transfer speeds will be slower until this
nishes.
RAID I16
ARRAYx Creating
Creating the Xth RAID array.
RAID I17
ARRAYx Resyncing
Recycling the Xth RAID array. Transfer speeds will be slower until this
nishes.
RAID I18
ARRAY xRebuilding
Rebuilding Xth RAID array. Transfer speeds will be slower until this nishes.
RAID I19
ARRAYx 0 Filling
Deleting data completely by lling zeros into Xth RAID array.
DISK I20
DISKx Formatting
Formatting the Xth hard drive.
DISK I22
DISKx 0 Filling
Deleting data in the Xth hard drive.
SYSTEM
I23
Initializing
Initializing the system.
Network I24
Setting Cong
Conguring network settings (such as querying DHCP for an IP address).
SYSTEM
I25
F/WUPDATING
Updating the TeraStation's rmware. Do not turn off the TeraStation until
the update is complete.
Web Setting I26
Initializing
Initializing web conguration.
iSCSI
I30
Connected
A computer is connected to the volume. Before turning off the computer,
disconnect the TeraStation (page 11).
Press FuncSW
I31
New Diskx ready
The new drive is ready to mount. Press the function button to mount it.
Set From Web I32
New Diskx ready
The new drive is ready to congure. Use the conguration utility to
restructure the drive or rebuild a RAID array.
These examples show the two-line display of a TS-IXL TeraStation. Rack-mount TS-RIXL TeraStations
have a slightly different LCD display, with the two lines of information displayed on a single line. Scroll
horizontally to view the rest of the information.