User`s guide

Rack Space Requirements
007-4403-003 21
Table 2-3 shows the power and size specifications for external RAID storage systems.
Rack Space Requirements
A 2-channel SGI Media Server requires three standard rack units and an 8-channel
SGI Media Server requires seven rack units. The SGI Media Server occupies a standard
19-inch rack. In addition, each external SGI TP900 disk array requires 2 rack units, and
each SGI TP9100 disk array requires 3 rack units each and resides in a standard 19-inch
rack.
The following sections show the space requirements for sample configurations for the
SGI Media Server.
Sample Space Requirements for Model 325
Table 2-4 shows the rack space requirements for a two-channel Model 325 with TP900
storage.
Table 2-3 Power and Size Specifications for the External RAID Storage System
Specification Value
Input Volts Dual internal rack power distribution to enclosures, single phase, 250 VAC
(180 minimum, 257 maximum), 50/60 Hz, 16A (25A circuit breakers)
Dimensions 13.34 cm x 44.45 cm x 50.0 cm (5.25” x 17.5” x 19.68”) for height, width, and
depth, respectively
Weight Approximately 35 kg (77 lbs) fully loaded, 9 kg (19 lbs) empty
Table 2-4 Two-Channel Model 325 Space Requirements
Component Rack Space (U)
Origin 300 or Origin 350 (2-CPU) with 2 PCI-VIDAUD-MSB-B cards 2
1 MSB-REARPANEL-B panel 1
RM 610 disk array 2