Full Product Manual
38
Lamp test
All segments and LEDs
light up.
Software revision Low-level selected
Low-level selected from the
low-level menu.
Software number
8.8.8
DISPLAY SEQUENCE AT START UP (EVERY PARAMETER IS DISPLAYED FOR 2 SECONDS)
IMPORTANT Please read the following before starting the
device.
Verify that all accessories are linked to the ground lug and
connected to the to the control system.
A minimum flow of 68 LPM (18 GPM) is required. Make sure
that all valves are open in the hot tub plumbing and that
the water flow is sufficient between the main pump and
the water heater.
Turn on the breaker.
IN.FLO DRY-FIRE PROTECTION
At start up, the in.flo’s detector verifies the water flow accord-
ing to the following sequence:
The Pump 1 or the circulation pump runs for a period of 2 to
5 minutes.
The display will show “- - -“ during the flow verification. After
this time, the system confirms if flow is adequate or not.
If the flow is sufficient, the temperature of the water is
displayed on the keypad screen. When the water has reached
the consigned temperature plus 0.45°C (0.8°F), the water
heater turns off.
POWER UP AND BREAKER SETTING
BREAKER SETTING