CONNECTING HIGH VOLTAGE ACCESSORIES: NORTH AMERICAN HEAT RECOVERY MODEL IN.YJRE
These tabs require high-voltage accessories to have straight, non-insulated, female quick-connect terminals for all connec-
tions, including ground. Refer to the following tables for correct connections. Note that all female terminals must be correctly
and completely seated on the PCB tab for proper current ratings.
Make sure all accessories are linked to the bonding lug connector located on the side of the hot tub pack.
DIRECT OUTPUT
Voltage 120 V
Green / ground P27
Black / line P25
White / common P18
RGB LEDS IN.LU.ME 1A*
Switch P38
DIRECT OUTPUT
Voltage 120 V
Green / ground P28
Black / low speed K6-P
Red / high-speed K4-P
White / common P19
OZONATEUR
Voltage 120 V
Green / ground P30
Black / line P23
White / common P35
Light (12 V DC, 1A)*
Switch P33
CONNECTIONS
WIRING DIAGRAM W2000, W2001
* Combination of both outputs is limited to 1A.
This table shows typical connections. OEMs may have a different connection scheme.
31