CONNECTING HIGH VOLTAGE ACCESSORIES: NORTH AMERICAN MODEL IN.YJ
Wires to connect high voltage accessories must have 0.25” quick-connect terminals.
These tabs require high-voltage accessories to have straight, non-insulated, female quick-connect terminals for all connec-
tions, including ground. Depending on where the connections are made on the in.yj pack PCB, 120 V and 240 V accessories
are supported. Refer to the following tables for correct connections. Note that all female terminals must be correctly and
completely seated on the PCB tab for proper current ratings.
Make sure all accessories are linked to the bonding lug connector located on the side of the hot tub pack.
DIRECT OUTPUT
Voltage 120 V 240 V
Green / ground P27 P27
Black / line P25 P25
White / common P18 P14
LIGHT 12 V DC, 1A*
Switc h P33
HEAT.WAVYJ
Green / ground P5
Black / line P3
White / common P4
RGB LEDS IN.LU.ME 1A*
Switch P38
DIRECT OUTPUT
Voltage 120 V 240 V
Green / ground P28 P28
Black / low speed K6-P K6-P
Red / high-speed K7-P K7-P
White / common P19 P15
PUMP 2
IN.YJ3 ONLY
Voltage 120 V 240 V
Green / ground P29 P29
Black / low speed K5-P K5-P
White / common P20 P16
OZONE
WORKING WITH PUMP 1 LOW SPEED
Voltage 120 V 240 V
Green / ground P30 P30
Black / line P23 P23
White / common P35 P37
CONNECTIONS
WIRING DIAGRAM W2000, W2001
* Combination of both outputs is limited to 1A.
This table shows typical connections. OEMs may have a different connection scheme.
30