WIRING DIAGRAM - W2000, W2001 W2000, W2001 OVERVIEW Probe connectors (heat.wav's low voltage cable or regulation probe and overheat captor model-re) heat.wav power connection Light output (12 V DC) Bonding lugs Communication link (in.touch or in.
WIRING DIAGRAM - W2000, W2001 CONNECTIONS CONNECTING HIGH VOLTAGE ACCESSORIES: NORTH AMERICAN MODEL IN.YJ Wires to connect high voltage accessories must have 0.25” quick-connect terminals. These tabs require high-voltage accessories to have straight, non-insulated, female quick-connect terminals for all connections, including ground. Depending on where the connections are made on the in.yj pack PCB, 120 V and 240 V accessories are supported. Refer to the following tables for correct connections.
WIRING DIAGRAM - W2000, W2001 CONNECTIONS CONNECTING HIGH VOLTAGE ACCESSORIES: NORTH AMERICAN HEAT RECOVERY MODEL IN.YJ-RE These tabs require high-voltage accessories to have straight, non-insulated, female quick-connect terminals for all connections, including ground. Refer to the following tables for correct connections. Note that all female terminals must be correctly and completely seated on the PCB tab for proper current ratings.
WIRING DIAGRAM - W2000, W2001 CONNECTIONS COMPLETING THE INSTALLATION Strain relief bracket Foam gasket Molded strain relief channels For 12-3 /14-4/14-3 cable size For 14-3 /18-3 cable size Output cable opening size 4
WIRING DIAGRAM - W2000, W2001 ELECTRICAL WIRING ELECTRICAL WIRING: ALL MODELS Bonding lugs Main power entry WARNING! Disconnect power before starting electrical work. Wiring must be completed by a qualified electrician and must be done in accordance with the local electrical code. Do not use a wire gauge bigger than 8 AWG. Main power entry To complete the electrical connections of the in.yj control system you will need a Phillips screwdriver and a flat-head screwdriver.
WIRING DIAGRAM - W2000, W2001 ELECTRICAL WIRING ELECTRICAL WIRING: NORTH AMERICAN MODEL Refer to wiring diagram in the enclosure box lid for more information. 120 V (3 WIRES) 240 V (4 WIRES) DO NOT REMOVE THE BROWN WIRE. Insert each wire into the appropriate socket of the main entry terminal block according to the color code indicated on the sticker. Use a flat screwdriver to tighten the screws on the terminal.
WIRING DIAGRAM - W3000 W3000 7
WIRING DIAGRAM - W3000 CONNECTIONS CONNECTING HIGH VOLTAGE ACCESSORIES: ALL MODELS Two options are available with Y Series hot tub packs for connecting high voltage accessories: 0.250” quick-connect terminals, or AMP connectors conform to industry standards. CONNECTING HIGH VOLTAGE ACCESSORIES: NORTH AMERICAN MODEL IN.YE For the connection to the 0.
WIRING DIAGRAM - W3000 CONNECTIONS HEAT.WAV WATER HEATER CONNECTIONS Live Return Ground All Y Series systems come with a high performance heat.wav heater. With no pressure switch, it features in.flo integrated dry-fire protection. in.flo flo Regulation probe The heat.wav heater is factory configured for 240 V / 4 kW, but it can be converted to a dedicated 120 V / 1 kW by simply adding a cable connection. (120 V conversion is available on North American in.ye-3 models only). The heat.
BREAKER SET TING POWER UP AND BREAKER SETTING IMPORTANT Please read the following before starting the device. Verify that all accessories are linked to the ground lug and connected to the to the control system. A minimum flow of 68 LPM (18 GPM) is required. Make sure that all valves are open in the hot tub plumbing and that the water flow is sufficient between the main pump and the water heater. Turn on the breaker. IN.FLO DRY-FIRE PROTECTION At start up, the in.